The SRT-100 Vision™ has many unique features that make treatment safe, comfortable and effective.
For patients and physicians who want the ultimate in advanced Superficial Radio Therapy technology, Sensus Healthcare offers the SRT-100 Vision™ —the next generation of innovation in our powerful arsenal against non-melanoma skin cancer and unsightly keloid scarring.
Built with all the same great features and remarkable efficacy that distinguish the original SRT-100™, the SRT-100 Vision™ delivers the precise, painless calibrated dose of Superficial Radio Therapy patients and physicians expect, but offers additional features—most notably high-frequency ultrasound for imaging.
With a high-frequency ultra-sound guidance system, the SRT-100 Vision™ allows physicians to view treatment areas while they are being treated. This “see and treat” capability allows basal and squamous cell carcinomas, as well as keloid tissue, to be assessed more thoroughly so treatment can be targeted more precisely. When the ultrasound technology is placed over the treatment area, physicians can assess the lesion to see how deep it is and fine tune the exact amount of radiation needed. This will ultimately help tailor each patient’s treatment protocol when physicians are able to see how the lesion is progressing with each treatment session. Not only this, but each treatment session is recorded for patient records with the LesionCam™.
SRT-100+ Vision™ has many unique features that make treatment safe, comfortable and effective.
Laser Positioning
For precise beam port positioning and re-positioning on the treatment area.
System Lesioncam™
Provides lesion photo-registration and a video of treatment for patient records.
Rad check
Pre-treatment energy verification as part of a daily QC program for precise and accurate x-ray delivery.
Touch-screen control console
Facilitate the set up, initiation, monitoring and termination of exposures. The module can be located remotely.
Audio/visual monitor
Provides constant bi-directional patient communication.
Automatic AL and CU filter magazine
Applies the correct filter to match the selected energy and beam depth.
Electronic medical records
Organizes patient scheduling and record management to optimize workflow.
Dosimetry – record and verify
Calculates proper dosing and measures each dose administered during treatment to ensure patient safety and optimal outcomes.
Radcheck™ QC
Automatically confirms system calibration each time the system is initiated to ensure the patient is receiving the correct dose and eliminates the need for un-scheduled calibrations.